Loop detectors
LD200 SERIES

Vehicle Loop Detector

Click to enlarge (16KB)

The LD200 series are dual channel inductive loop detectors. The use of the microprocessor based technology enables a large number of functions to be incorporated into a small package. The LD200 series is easy to set-up and install.

Typical applications include safety loops, arming loops and entry or exit loops.

Standard features of the detector are:

  • Reset Switch.
    • The reset switch enables the detector to be manually reset during commissioning and testing. This results in the detector re-turning the sensing loops and becoming ready for vehicle detection.
  • Switch selectable Sensitivity.
    • Eight sensitivity settings are available on the switches to allow flexibility in configuration.

1.
High
0.01%
2.
.
0.02%
3.
.
0.05%
4.
.
0.1%
5.
.
0.2%
6.
.
0.5%
7.
.
1%
8.
Low
2%

Pulse Relay Selection.

The detect relay may be configured for a pulse output and to energize on detection of a vehicle or when the vehicle leaves the loop.

Selectable N/O or N/C output.

Internal jumpers enable the output relay contacts to be configured for normally open or normally closed contacts.

Direction Logic.

This feature enables the detector to give a pulse output on relay 1 for a vehicle traveling from loop 1 to loop 2, and a pulse output on relay 2 for a vehicle traveling from loop 2 to loop 1.

TECHNICAL DATA

1. Power Requirement

LD200 110VAC / 220VAC

LD201 12 VAC/DC

LD204 24 VAC

2. Presence/Pulse Relay 0.5A
3. Indicators LED indicators show: Power, and state of each loop detect.
4. Detector Tuning Range 15-1500µH.
5. Protection Loop isolation transformer, zener diode and MOV.
6. Connector 11 Pin Connector on rear of unit
7. Dimensions 75mm(HIGH) x40mm(DEEP) 29” x 1.6” x 3”
8. Operations temperature -40°C to +80°C -40°F to 176°F
9. Storage temperature -40°C to +85°C -40°F to 185°F
10. Humidity up to 95% non-condensing

To download these specifications in pdf format (16KB) please click the icon.