Inductive loops
MODEL A (HOT ASPHALT OVERLAY)
Step
Installation instruction
1.
Unfold loops and lay down flat in shop or warehouse preferably 24 hours before installation.
2.
At the installation site: unfold loop and lay on surface.
3.
Slip the white PVC slides over the expansion-contraction joints and tape ends securely to conduit with electrical tape.
4.
Secure loop to the base at regular intervals and at the corners with asphalt tape / duct tape / small amounts of hot asphalt. Secure the lead (tail) in similar fashion.
5.
Make sure during installation of asphalt that installation equipment does not uplift the loop. Loops may be safely run over the equipment. However, Never-Fail Loop Systems bears no responsibility for faulty installation methods.
6.
Check loop for continuity and resistance to ground.
WARNING

READ BEFORE INSTALLATION

Make certain that each expansion / contraction joint is covered by a slide and is secured as described by the aforementioned instructions prior to any equipment passing over the loop. Failure to do so releases Never-Fail Loop Systems from obligations of the warranty.

To prevent possible cracking or warping of newly installed asphalt, a minimum cover of 2.5 inches (6 cm.) is strongly recommended.

NOTE: When properly installed, Never-fail Loop Systems will provide many years of trouble-free performance.