Inductive loops
MODEL C (CONCRETE OVERLAY)
Step
Installation instruction
1.
Remove loop(s) from box, unfold, verify loop and lead-in dimensions and test.
2.
Lay out the loop on surface or rebar.
See drawing for circular design (25k) or rectangular design (24k).
3.
Slide sleeves over the expansion / contraction joints.
4.
Secure the sleeves to the loop with electrical tape in order to prevent premature movement of the sleeves during the pouring of the concrete.
5.
Secure the loop(s) directly on top of the reinforcing steel with ty raps.
Secure the lead-in underneath the reinforcing steel with ty raps.
In case of existing concrete / asphalt subbase, secure loop to subbase with asphalt tape or similar product.
6.
It is permissible for loop joints to come in contact with installation equipment. However, it is advisable to avoid contact whenever possible.