Model F-38 Loop Detectors are designed for just about any installation.

  • Cut-in.
  • Hot asphalt overlay.
  • Concrete overlay.
  • Temporary above ground application

ADVANTAGES

Can be laid down on rebar without spacers. (if applicable) Wires sealed in rubber asphalt filled polypropylene conduit.

Completely tested prior to shipment:

  • No splices.
  • Shipped ready to install.
  • Patented expansion / contraction capabilities.
  • Significantly lower shipping cost.
  • Reduced maintenance cost.
  • Needs only a 3/8" (9.5 mm) saw-cut slot.

SPECIFICATIONS

Loops shall be constructed of 3/8" (9.5 mm) O.D. hydraulic flex hose. Heads and tails shall be completely filled with rubberized asphalt. Tees at junction of head/tail shall be schedule 80 CPVC. Lead-ins shall be twisted 3 times per foot (30 cm) minimum. Loop shall have one continuous wire through the loop head and lead-in to prevent loop malfunctions due to splicing. Wire shall be 20 gauge, stranded, teflon-coated, single conductor. Military spec. MIL-W-16878/4 Type E All Loops shall be tested four ways prior to shipment. ("megger", ohms, quality, inductance).